PROMEL® FGP-05e
Fire and gas detection
Mod. FGP-05e
The new controller PROMEL FGP-05e has been designed with the aim of maintaining the same layout and the same ease of use of its predecessor FGP-04, while improving flexibility, safety and functionality. Description: Each I/O card is equipped with on-board processor. Thanks to the distributed architecture, the diagnostic coverage and the safety of the overall system have been improved.
The system can manage up to four discharge areas. For each zone it is possible to manage OUT OF SERVICE status on:
- fire detection sensors
- manual discharge push buttons
- discharge actuating devices
- optical and acoustic signalling devices
- alarm signalling to other systems
- fault signalling to other systems.
All these operations can be executed independently, without compromising the management of non-affected zone.
The new operator interface, completely redesigned, provides full information on the operating conditions of the system by means of led and alpha/numeric display.
Many logical functionality have been redesigned to take into account Customers’ needs and past experience, while maintaining full compliance with existing regulations.
The main innovations in functionality concern:
- discharge management and time delays;
- discharge inhibit management;
- Signals Tag editing and Network Configuration;
- self-diagnostics;
- EGD protocol.
The software is designed to allow changes only within specific functions and by authorized personnel.
This ensures full compliance with the safety parameters required by CPD Directive.
CERTIFICATIONS
- CPD Certification Directive on construction products (CPD) 89/106/EEC. Certificate 0068-CPD-003/2010 rev.1, issued by the Supervisory Body notified by the European Union no. 0068. The certification is for EN 12094-1 and EN 54-2 standards.
- GOST-R 653325-2009 Fire techniques. Means of fire automatics. The general technical requirements. Test methods. Certification no. S-IT.PB25.B.01383
Main reference standard & norms
- EN12094-1 Fixed firefighting systems – Components for gas extinguishing systems – Requirements and test methods for electrical automatic control and delay devices
- EN 54-1 Fire detection and fire alarm systems – Introduction
- EN 54-2 Fire detection and fire alarm systems – Control and indicating equipment
- EN 54-4 Fire detection and fire alarm systems – Power supply equipment
Other applicable Directives
- EMC Directive 2004/108/CE
- Low Voltage Directive 2006/95/CE
Main characteristics of the FGP family:
Function Comparison Table | FGP04 | FGP05e | FGP05s |
---|---|---|---|
EN54-2 Compliance | X | X | X |
EN12094 Compliance | X | X | X |
CPD / CPR Certification | X | X | |
GOST Certification | X | X | |
Rating SIL 2/3 for HW / SW Configuration | X | ||
Modular configuration | X | X | X |
Redundant Power Supply | X | X | X |
I/O Modules with on-board Microprocessor | X | X | |
CPU boards installed on rear slots | X | X | |
Multizone Management (up to 4 zones) | X | X | |
Single CPU Configuration | X | X | X |
Dual CPU Configuration | X | X | |
Triple CPU Configuration | X | ||
TMR Configuration | X | ||
Serial Modbus Protocol | X | X | X |
Ethernet Modbus Protocol | X | X | X |
Ethernet EGD Protocol | X | X | |
HMI on Frontal Panel | X | X | X |
Direct Field Wiring connection | X | X | X |
Line check on inputs (open / short circuit) | X | X | X |
24VDC Outputs LIne Check (open / short circuit) | X | X | X |
Line check on FVC outputs (open / short circuit) | X | X |